Number of Controlled Axes: Suitable for controlling 1 axis.
Component Series: 22, belonging to the 20…29 series with unchanged installation and connection dimensions.
Installation Method: The housing can be wall-mounted (represented by W).
Digital Inputs/Outputs: There are 8 digital inputs and outputs.
Bus Connection: Without bus connection (indicated by the final 0).
Operating Voltage: 18 to 36VDC.
Power Consumption: 8W.
Voltage Input: Channel number is 4, measurable range is +10V to –10V (maximum +15V to –15V), input resistance is 200kΩ±2%, resolution is 5mV, nonlinearity is <10mV, and the maximum calibration tolerance is 40mV (with factory settings).
Current Input: Channel number is 4, input current is 4mA to 20mA, input resistance is 100Ω±0.2%, leakage current is 0.1 to 0.4% (500Ω between pin “Iin 1–” and “analog_GND”), and resolution is 5μA.
Impedance Input: Channel number is 4, input voltage is -10V to +10V, input resistance is 100Ω±0.2%, resolution is 5mV (range ±10V), 2.5mV (range 0…10V), nonlinearity is <10mV, and the maximum calibration tolerance is 40mV.
Logic Level: Logic 0 (low) ≤5V; Logic 1 (high) ≥10V to UB; Re=3kΩ±10%.
Voltage Output: Channel number is 4, standardized output voltage is -10V to +10V (maximum -10.7V to +10.7V), maximum output current is 10mA, and minimum load is 1kΩ.
Current Output: Channel number is 2, output current is standardized to 4mA to 20mA, non-standardized maximum is 23mA, and maximum load is 500Ω.
There are no reviews yet.