The following are some main parameters of IS415UCVHH1A:
Input and output signals:
Input signal: 0-5V, 1-5V, 0-10mA, 0-20mA, 4-20mA, 0-10V, -10V ~ +10V and other user specific specifications;
Output signal: 0-5V, 1-5V, 0-10V, -10V ~ +10V, 0-10mA, 0-20mA, 4-20mA and other user specific specifications.
Power requirements: Input voltage is 24-75V DC; In the case of power supply, other power supply methods can be selected, but usually use 24V DC backplane power supply.
Digital signal input and output:
With 3 digital signal input ports, the input signal is 5-24V DC, photoelectric isolation, such as receiving pulse/direction/enable signals;
Has 1 digital output for error signal output.
Subdivision and current setting:
Dip switch can choose 8 subdivisions, including 400, 800, 1600, 3200, 6400, 12800, 25600, 51200;
The DIP switch can select eight current levels, such as 2.4A, 3.2A, 4.4A, 4.4A, 5.6A, 6.4A, 7.0A, and 7.8A.
Operating temperature: -20℃ to + 70℃.
Other features:
Support DIN35mm rail installation or wall mounting, compact design, easy to upgrade the old site;
Full isolation design, with high performance EMC anti-interference ability;
Equipped with RS485 (Modbus RTU protocol) communication interface, can achieve remote monitoring;
It has the power failure storage function and supports memory modes such as power-on continue, run, and stop.
GE IS415UCVHH1A controller board is available from the shelf
The following are some main parameters of IS415UCVHH1A:
Input and output signals:
Input signal: 0-5V, 1-5V, 0-10mA, 0-20mA, 4-20mA, 0-10V, -10V ~ +10V and other user specific specifications;
Output signal: 0-5V, 1-5V, 0-10V, -10V ~ +10V, 0-10mA, 0-20mA, 4-20mA and other user specific specifications.
Power requirements: Input voltage is 24-75V DC; In the case of power supply, other power supply methods can be selected, but usually use 24V DC backplane power supply.
Digital signal input and output:
With 3 digital signal input ports, the input signal is 5-24V DC, photoelectric isolation, such as receiving pulse/direction/enable signals;
Has 1 digital output for error signal output.
Subdivision and current setting:
Dip switch can choose 8 subdivisions, including 400, 800, 1600, 3200, 6400, 12800, 25600, 51200;
The DIP switch can select eight current levels, such as 2.4A, 3.2A, 4.4A, 4.4A, 5.6A, 6.4A, 7.0A, and 7.8A.
Operating temperature: -20℃ to + 70℃.
Other features:
Support DIN35mm rail installation or wall mounting, compact design, easy to upgrade the old site;
Full isolation design, with high performance EMC anti-interference ability;
Equipped with RS485 (Modbus RTU protocol) communication interface, can achieve remote monitoring;
It has the power failure storage function and supports memory modes such as power-on continue, run, and stop.